Access control Configer
Wiring Port
- +12 V working power Supply, input rang DC9-13.8V
- GND: Ground
- NO:- Normally open relays, current carrying capacity DC10A/30V]
- COM:- Common pin of relays, current carrying capacity DC10A/30V
- NC:- Normally close relay, current carrying capacity DC10A/30V
- OPEN:-Button switch , low level May cause open.
- DOOR:- Door status detector, connected to the door detector, low level means door closed
- ALM:- Alarm output port, be low level when emergency occurs, currency is 100mA.
- WG0;- Wiegand 26 reader data lines(data 0)
- WG1:-Wiegand 26 reader data lines(data 1)
- BELL:- the doorbell switch
Indicator:
- POWER:- Power indicator.
- MODE:-Mode light constantly means that has entred the management state MODE flashes means normal state.
- OK :- Ok Flashing means unlocked.
Reset Button (Reset)
Hold down the RESET button, wait for 2 seconds until beeps, release it, access controller would back to factory default status (management password back to 1234). after that , if hold RESET 5 second until beeps , release the RESET , it will initialize automatically and all the card data remote control manage password will be deleted and reset to factory defaults. Remove all cards, remove all the remote control, restoration of all parameters, recovery management password 1234)